Why Eagle Eye GFL-1000? The cost of bad insulation or grounding in you power system can be tremendous. It may even cause power break-off which is costly to repair. Fast localization and elimination of insulation faults will be significant for electricians and technicians. It is also required by DIN VDE 0100-410 (VDE 0100-410): 2007-06 chapter 411.6.3.1 and IEC 60364-4-41 chapter 413.1.5.4. Eagle Eye GFL-1000 is developed to quickly detect, track and locate virtual grounding faults on DC systems. This spares you from hours of unnecessary troubleshooting and helps to increase the reliability of your electrical equipment.

Method
There is a loss of electricity to the ground in the breakage of the busbar and thus generates a faulty "grounding". When testing leads of the GFL-1000 are connected to the ground and busbar, there will be a return circuit. Signal generator (main unit) will send a low-frequency voltage signal of 0.1Hz~1000Hz between the testing target and grounding malfunctioned circuit. The breaking point will generate leaking current. As the grounding receiver (signal receiver) moves in the circuit, different points in the circuit will have different reaction in the indication of sound warning. It will pinpoint the cable fault based on the sound volume in the signal receiver.
Eagle Eye Data View
Testing data of insulation could be recorded and printed as a report with Eagle Eye DataView software.
GFL-1000 Features
- Two functions in one: Insulation tester and ground fault locator.
- Test and record insulation status of facilities.
- Powerful management DataView Software on PC for data analysis.
- No disconnection of the electrical installation – ground fault location is carried out during operation.
- Fast locations for ground fault even when cables are buried
- Signal-generator with adjustable frequency and voltage
- Reflects aging status of facilities for further reparation
- Reduced maintenance and repair costs
- Compact & rugged design
GFL-1000 Technical Specifications
- Measuring range: V testing: 0.00-1000V
- Min resolution: Voltage: 0.1V Insulation R: 0.01 MΩ
- Accuracy: Voltage: 1%rdg±8dgt ; Insulation R: 0.5 MΩ-100 MΩ 5%rdg±6dgt﹥100 MΩ: 10%rdg±6dgt
- Output signal: voltage: 0-1000V±10% Frequency: 1-1000Hz
- Power consumption: ≥4 hours(continuous operation)
- Memory: 32k×8bit Non Volatile SRAM
- Displaying screen: 128×64 pixels LCD
- Communication: USB interface
- Dimension: 14.5″L x 11.4″W x 9.8″H
- Humidity: 80%R.H
- Testing accuracy: ≤0.25MΩ
- Sensor aperture: 2.3″
- Battery:Li-ion
- Weight: 15.4 lbs.
- Temperature: 23°F to 104°F
- Power voltage:DC 8.4V