 A load bank is a crucial part of any company’s power system. A load bank acts as battery testing equipment making sure that the power source is working correctly. It develops the load, applies the load to the power source, and converts the power output of the source. A load bank mimics a real load to see how the power source will react.


An important part of battery monitoring is a battery discharge test. If there is a power outage, it is important to make sure your battery will have the power to keep you running. The only way to do this is through regular battery monitoring systems. Regular testing will ensure your batteries a long life. Eagle Eye Power Solutions have the top load banks in the industry ranging from DC banks like the LB-24-300 to AC banks like the LB-60-30 for all of your battery monitoring needs. Please click on the specified product for more details on that particular model.

 
 
 
84(024) 3750 5142
tshops - sieu thi thiet bi cong nghiep

DC LOAD BANKS

LB-24-300 (24Volt, 300Amp)

The LB-24-300 is specially designed for a discharge test, capacity test, battery maintenance, engineering examination and other tests for 24VDC power units by applying a load up to 300Amps. Standard available loads are 0-100Amps, 0-200Amps, 0-300Amps. Resolution 1Amp. The LB-24-300 is your smart, safe and environmentally-friendly load bank. *Wireless communication is optional for real-time monitoring during discharge


LB-24/48-300 (24/48Volt, 300Amp)

The LB-24/48-300 is specially designed for a discharge test, capacity test, battery maintenance, engineering examination and other tests for 24/48VDC power units by applying a load up to 300Amps. Standard available loads are 0-100Amps, 0-200Amps, 0-300Amps. Resolution 1Amp. The LB-24/48-300 is your smart, safe and environmentally-friendly load bank. *Wireless communication is optional for real-time monitoring during discharge.


LB-48-300 (48Volt, 300Amp)

The LB-48-300 is specially designed for a discharge test, capacity test, battery maintenance, engineering examination and other tests for 48VDC power units by applying a load up to 300Amps. Standard available loads are 0-100Amps, 0-200Amps, 0-300Amps. Resolution 1Amp. The LB-48-300 is your smart, safe and environmentally-friendly load bank. *Wireless communication is optional for real-time monitoring during discharge.


LB-125-300 (125Volt, 300Amp)

The LB-125-300 is specially designed for a discharge test, capacity test, battery maintenance, engineering examination and other tests for 125VDC power units by applying a load up to 300Ams. Standard available loads are 0-100Amps, 0-200Amps, 0-300Amps. Resolution 1Amp. The LB-125-300 is your smart, safe and environmentally-friendly load bank. *Wireless communication is optional for real-time monitoring during discharge.


AC LOAD BANKS

LB-60-30 (AC Load Bank)

The LB-60-30 LOAD BANK is designed to provide a temporary load for field servicing and testing 120/240 volt single phase or 120/208 three phase 60HZ generators and inverters. The LB-60-30 load bank is air cooled and completely self contained. It has a 30KW 3 phase and a 20KW single phase load.


LB-60-80 (AC Load Bank)

The LB-60-80 LOAD BANK is designed to provide a temporary load for field servicing and testing 480VAC and 208VAC three phase, 60HZ generators and inverters. The LB-60-80 load bank is air cooled. A 120VAC outlet is required to operate the fans and relays. The load is 100KW at 480VAC and 80KW at 208VAC. This unit will also test 120VAC & 240VAC single phase.


BATTERY CHARGER / DISCHARGER / ACTIVATOR

LB-1000 (Battery Charger/Discharger)

Eagle Eye LB-1000 is a compact unit for daily battery maintenance. It offers 3 complete solutions: battery charger, battery discharger and battery activator, which will facilitate your battery maintenance program and your battery monitoring system. These three functions could be used individually or comprehensively. When used comprehensively, lag-out battery will experience low-volt constant current charging and discharging of single or multi-cell batteries (1~99A). By activating the disabled Active Material of the battery monitoring electrode plate, it amends the battery malfunction caused by chemical failure and thus boosts the capacity of an old battery. Activation curve and certain parameters (e.g.: voltage and resistance) will display on screen as activation ends.